Applies to:

PcVue all versions


Symptom:

The Event Viewer shows the following looped message “List full type=0 LinkEnd count=8192 max=8192” and sometimes PcVue crashes.


Details:

This is a specific case to illustrate Errors 44 and 45: list full %s kb article.

Here, the number of Scada Basic functions in a queue is too high (more than 8192) for a specific Scada program.

This behavior happens when:

– Too much Event Actions have been triggered.

– Some Cyclics Actions are configured with a too fast period.

PcVue is not able to treat all the functions call and stackes it in a linked list limited to 8192.

At the end, the list is full and then the message is prompted.