3D 61850 64 bits 7u51 AA Active Directory ActiveX Addon Adeunis ADO ADODB AE Alarm Alarm sythesis Alarm viewer Alarming Alarms Alert Animations ANSI Anywhere USB Applet Application Architect Application Explorer Applicom Architect Archive Archives Archiving ASCII Audit Autosize Average AVI BACnet Big data Bottleneck Broadcast Byte CFR21 Chart Control CHRONO Cimway Client Code Page Codec Comm.dat Command line Commend Communication Compatibility Configuration environment Copyfield Cosmos DB Cron CSV Cyclic DALI Dashboard Data acquisition Data Export Database DataVue DCOM DDE DDE Server Debug Demo Demo project DEP Diagnostic DirectLink DNP3 Documentation Domain Domain controller Dongle Drawing Dream Report DVD extras EDE Email Enable Equipment Error Error ID Error messages numbers ESXi Ethernet Ethernet direct Ethway Event viewer Events Excel Export Expression FAQ File Fipway Firewall Font Form FrontVue General GEZE Gmail Graphics Grid Groupalarm Handled Handles Hardcopy HDS Historic HMI HP Icx IEC IEC 61850 IIS Iks Import Installation Internet Internet Explorer Intravue IoT IP Izot Java JRE JSON Kerlink Key Keyboard KNX Language Libraries Library Licence Utility License License Utility Licensing LNS Log Log files Log viewer LogList Logoff LogViewer Lonworks LoRaWAN Memory Memory leak Messages Migration Mimic Modbus TCP/IP Modem Molex Moxa MQTT MSSqlServer Multimedia Multiregion Multistation Multitech MXview MySQL NetBIOS Network Network analyser Networking News NL220 Obsolete articles OCPP ODBC Offline OPC OPC-DA Client OPC-DA Server Open Weather Map Operating System Password PcVue PcVue 10 PcVue 12 PcVue as a service PcVue features PDF Performance PlantVue PLC Print Private Process Profibus Project management Protect Tools Protocol Provider Proxy Pulse Quickstart Recipe Region Regular Release info Replication Rest RLM RTE Ecowatt Russian S7 S7 Fetch/Write S7 ISO SAIA Sample project Scada Basic Schedule Scheduler Scripting Security Segmentation Sentinel Setup SG Siemens Sigfox Silent installation Simulation Single line diagram Smart Generator SMS SnapVue SNMP Solar SQL SQL Server SQL Server 2014 Start Startup String Substation Automation Summer SV Manager Toolkit Svmgr SW1000 Switch Syslog System Text TFTP Threads Time Timeout Timer Timestamp Toolkit Tools Touchscreen TouchVue Trace Treatments Trend Trend viewer Trends Troubleshooting Unitelway Upgrade Useful tools Username Varconf.dat Varexp Variables VBA Version control Versions Virtual machine Virtualization VmWare VPN W7x64 WAGO Watchdog Web Web Services Web Services Toolkit Web.configsvmobile WebScheduler Webvue Windows domain Windows Terminal Server Windows update Winter Workaround Workspace Write Commands
Article samples

[KB784] How to select an object behind another one?

Applies to: PcVue all versions. Summary:  If you try to click to select the Red rectangle PCVUE will select the Yellow circle. Solution: Of course you can use the Mimic […]

983
Article samples

[KB785] Auto-Acknowledged Alarms

Applies to: PcVue all versions. Summary: How to configure Auto-Acknowledged Alarms ? Solution: In C folder, edit the “PARAM.DAT” with notepad  Look for a line beginning by COLORWDWALARM, priority level,… […]

673
Article samples

[KB786] How to Reverse the Execution Sequence of Animations

Applies to: PcVue all versions since 6.04. Summary: This article explains how to change the order in which animations are executed, without rebuilding the mimic. Details: When you put two […]

605
Article samples

[KB787] Counting Write Commands in Your Application

Applies to: PcVue all versions. Summary: This article explains how to activate a log in the Event Viewer of the Supervisor to check the number of Write commands that are […]

763
HMI

[KB737] Display a special character like “delta”

Applies to: All versions of PcVue. Summary: How to display special characters in a PcVue text drawing element. Details: Open the Windows Character Map. The simple way to do this […]

102
WebVue

[KB735] WebVue and Authentication

Applies to: WebVue (from version 6.10 to 11.2) Summary: This article explains authentication methods and how they affect WebVue. Originator AK Details: Standard/default WebVue authentication WebVue implements its own authentication […]

588
WebVue

[KB734] Troubleshooting WebVue: Java 8

Applies to: PcVue from 8.1 to 11.1, Webvue Summary: This document describes how to solve known troubles met between WebVue and version 8 of Java RE, which includes a new […]

913
Data acquisition

[KB733] Double mapping on a CIMWAY frame

Applies to: PcVue 10.0 SP1, 11.0 onwards   Summary: Double mapping on a CIMWAY frame.Originator: EM    Details: It is now possible to map two variables to the same item […]

468
Historical data

[KB732] How to copy the contents of an HDS table to another SQL table or other relational database

Applies to: All PcVue versions including the HDS Originator: AD Summary: The SQL Server tools allow you to copy the contents of a table using two methods. On the fly […]

414
HMI

[KB731] Adding line breaks to the text of a Chart Control

Applies to:PcVue 11.1 and later. Summary:Line breaks in the text displayed in a Chart Control. Details:You can add line breaks to the text displayed in a Chart Control (Main title, […]

75
HMI

[KB730] Changing the Color Palette programatically

Applies to: PcVue 10.0 onwards Summary: The color palette can be changed by loading an alternative palette file (PALCOL.DAT) using VBA. Details: The VBA method ThisProject.LoadColors allows alternative color palettes […]

231
Scripting

[KB729] Using HARDCOPY in a Multi-screen Environment

Applies to: PcVue. All versions. Summary: Workaround, using a SCADA Basic script, to generate a screen hard copy when in a multi-screen environment.Originator: FABO Details: If you need to print […]

288
Alarms

[KB727] Populations & Alarm syntheses

Applies to: PcVue 11.1 and later Summary: This article explains the behavior when using Alarm Syntheses and Populations in a multi-station environment. Details: Introduction Alarm syntheses are used to create […]

298
Security bulletin

[KB725] Security bulletin 2012-1

Summary: This security bulletin follows an alert released on August 2011 and related to the ActiveBar components.We strongly recommend that users of the affected products apply the security measures described […]

787
Data acquisition

[KB724] SAIA Solution not to install the full PG5 suite

Applies to: Any PcVue version Summary: Making the SAIA driver works without installing PG5 suite Details: In order for the driver SAIA to work it is mentionned in the help […]

301
PcVue miscellaneous

[KB723] How to adjust the thread watchdog timeouts

Applies to: PcVue 8.10 and later Summary: How to adjust the thread watchdog timeouts. Details: Modification are made in PARAM.DAT, to the following lines: WATCHDOGMAIN,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 WATCHDOGMAINWARNING,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 WATCHDOGTHREAD,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 WATCHDOGTHREADWARNING,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 The timeouts […]

355
System

[KB722] PcVue VS SQL Server Compatibility

Applies to: PcVue 8.10 and later Summary: List of SQL Server version and PcVue version with which it has been qualified. Qualified means it has been tested and verified and […]

379
PcVue miscellaneous

[KB721] Workaround for VBA related handle leak

Applies to: PcVue 10.0 sp1 update (10.0.16061), 10.0 sp2 update (10.0.26008), 11.0 update (11.0.06032.9123) and later. Related articles: KB495 Summary: There is a handle leak from VBA (whether you use VBA […]

1690
Scripting

[KB719] Creation of Office 2013 document from PcVue VBA is not possible

Applies to: PcVue – all versions supporting VBA Summary: Office 2013 doesn’t install the component required to manipulate Office documents through VBA. This is a known problem and there is […]

201
System

[KB718] Data Execution Prevention for PcVue

Applies to: Windows Server operating systems Summary: For security reasons Windows Server 2012 onwards has Data Execution Prevention (DEP) enabled by default for all applications and services. After installation of […]

391
Useful tools

[KB717] Sentinel troubleshooting guide

Applies to: Sentinel keys (SuperPro, UltraPro, Sentinel Hardware Keys). Symptom: This guide is intended to assist our end-users troubleshoot issues with Sentinel keys. This guide provides in-depth troubleshooting of Sentinel […]

1280
Scripting

[KB716] Accessing SQL Server Database through VBA

Applies to: All VBA versions Summary: This VBA module allows to send read and write requests to a SQL Server database, using the ADO VBA Reference. The script is embbeded […]

861
Configuration environment

[KB715] Reading a string from a PLC

Applies to: PcVue all versions Summary: How to read strings from a PLC (example for Modbus TCP/IP). Details: To read strings from a PLC, the frame format has to be […]

344
Audit and diagnostic

[KB714] Scheduler Runtime Trace

Applies to: PcVue 10.0 sp2 update and later, 11.1 and later. (NOT in 11.0.) Summary: How to activate and interpret the Scheduler trace. Details: How to activate Use the SCADA […]

310
Useful tools

[KB712] Licence Utility

Applies to: PcVue up to and including version 11.0. Summary: How to use LicenceUtility.exe, a standalone utility to read and report the contents of a PcVue licence dongle. Details: To […]

514
Upgrade issues

[KB709] New WST dongle option

Applies to: PcVue 11.0 onwards Summary: From PcVue 11.0 access to Web Services is controlled by a specifc option in the protection key. Prior to PcVue 11.0 access to Web […]

155
System

[KB707] Compatibility between Direct-Link software, operating systems and virtualization solutions

Applies to: Direct-Link all versions Summary: This article describes the compatibility between between the (Molex) Brad Direct-Link software, operating systems and virtualization solutions Details: The attached file was up to […]

104
PcVue installation

[KB703] Installation Error – aimsiexecandlog.exe

Applies to: PcVue 10.0 SP2, from build 20032 and PcVue 11 update from build 06007 Summary: Prior to these versions, sometimes in the Install.log file, we find the following error: […]

132
HMI

[KB702] PcVue with Russian Characters

How to use PcVue and Russian characters You will need to use an operating system configured for Russian language. Here are the main modifications to do in the system’ settings. […]

221
Real time data

[KB701] How PcVue manages Alarm Synthesis (Treatment GROUPALARM)

Applies to: PcVue 10.0 SP1 Update 16051 and later Summary: How PcVue manages Alarm Synthesis and some performance figures of this function. It follows an improvement in PcVue 10.0 SP1 […]

357
Historical data

[KB700] How PcVue manages summer & winter time changes

Applies to: PcVue 9.0 and later Summary: This article describes how PcVue manages its archives during the summer and winter time change periods. It follows a verification plan made in […]

168
Configuration environment

[KB698] Configuring a cyclic action for fractional seconds

Applies to: All PcVue versions (including version 11) Summary: How to configure a cyclic action for fractional seconds. Originator: AK Details: When configuring a cyclic action in the Application Explorer the […]

187
Scripting

[KB695] VARIABLE mode REFRESH

Applies to: PcVue 9.0 SP2 and later Summary: How to force the refresh of a variable on a client station. Details: A new mode REFRESH has been added to the […]

340
Other Products

[KB692] How to create an IntraVue backup

Applies to: IntraVue Summary:This document decribes how to make a backup in IntraVue. Originator: VB Details: There are 3 ways to generate a backup in IntraVue. We suggest the option Generate […]

57
Other Products

[KB691] How to reduce the space required by the Mysql files when using IntraVue.

Applies to: IntraVue versions earlier than 2.1.0b. Summary: How to reduce the space required by the Mysql files when using IntraVue. Orginator: VB Details: The problem The folder C:\MySQL\data contains […]

74
Scripting

[KB690] Cypress Enable help files

Applies to: All versions of PcVue particulary 11 onwards Summary: The VBA-like scripting language called Cypress Enable was originally supplied with PcVue before VBA itself was integrated. The Cypress Enable […]

112
Sample projects

[KB689] X-Y plot from CSV file

Applies to: PcVue 10.0 but the XY Plot OCX could be used with any PcVue version supporting VBA. Summary: An example of an X-Y plot created using a freely available […]

244
Data acquisition

[KB688] Windows does not support Net DDE anymore.

Applies to: Windows XP and later. Summary: From Windows XP operating system, there is an uncompatibility issue regarding NetDDE. Details: NetDDE was removed from Windows XP, but was still available […]

100
Other Products

[KB687] How to reset triggering bit during generation ?

  Applies to: All Dream Report version Summary: When you want to generate automatically a report thanks to an event, you can configure a triggering bit and sometimes you need to […]

48
PcVue miscellaneous

[KB686] The Dynamic Busbar Coloring Add-on

Applies to: PcVue 11 onward. This article and its attachments were last updated for version 1.2 of the Add-on. Summary: The Topology Engine add-on is designed for dynamic coloring of […]

387
WebVue

[KB685] JRE 7u51 – New Java security policy

Applies to: WebVue for PcVue version 9.0, 9.0 SP1, 9.0 SP2, 10.0, 10.0 SP1 and 11. Summary: This article explains Oracle’s new security requirements for Rich Internet Applications and how […]

852
Data acquisition

[KB684] BACnet – Segmentation feature

Applies to: All PcVue version Summary:  This article describes how the segmentation of BACnet messages works and how to manage it with Pcvue. Details: The segmentation is the possibility to […]

101
General

[KB683] Central Project Management isn’t accessible, even if activated

Applies to: PcVue 11 onwards Symptom: Central Project Management dialog is dimmed. You are unable to change anything in it. Details: The Central Project Management dialog is locked. You can’t […]

130
Scripting

[KB682] Copy/Paste of a VBA symbol object

Applies to: PcVue – all versions supporting VBA Summary: If VBA symbol code of a duplicated symbol is not executed after a copy/paste, you need to check the symbol configuration. […]

230
Data acquisition

[KB679] How to configure Twincat Protocol

Applies to: All PcVue Versions including Twincat Protocol Summary: You will find attached, documentation explaining how to implement Twincat Protocol in PcVue Download attachments: Protocol TwinCATv1.2

245
PcVue 11

[KB678] About libraries supplied since version 11 and languages

Applies to: PcVue and FrontVue 11R Summary: This article contains information about the libraries supplied with version PcVue 11 and FrontVue 11. Details: Since the version 11, new sets of […]

126
HMI

[KB675] PcVue Form Controls and User Rights

Applies to: PcVue version 10.0 onwards Summary: This article explains how to control the command level variable when using PcVue Form Controls. Details: When you use PcVue Form Controls, the […]

219
Sample projects

[KB674] User-editable hysteresis values for each threshold

Applies to: PcVue version 10.0 onwards Summary: This program shows a workaround to make hysteresis values that can be edited by the user at runtime, plus user-editable delays on alarms. […]

299
Scripting

[KB673] How to use time-delayed alarms with SCADA Basic

Applies to: PcVue version 10.0 onwards Summary: This program shows how to create a delayed alarm using SCADA Basic, the alarm being activated by a manually controlled bit. This delayed […]

380
Communication interfaces

[KB672] Distributed variables properties

Applies to: PcVue version 10.0 onwards, PcVue 15 for deadband value and deadband type Summary: PcVue uses properties for each variable to specialize its behavior. In order to make them […]