[KB151] Using the “?VarName” syntax in SCADA Basic
Applies to: PcVue all versions. Summary: This article defines when you can use the syntax ‘?VarableName’ in SCADA Basic. Details: When you can use ‘?’ The syntax ‘?VariableName’ can only […]
[KB150] Using a Buffer with SCADA BASIC
Applies to: PcVue all versions. While the basic content of this article remains valid, details may have changed since it was written. Summary: This article gives advice on using buffers […]
[KB149] How to Start an Excel Macro with a SCADA BASIC Instruction
Applies to: PcVue all versions. Summary: This article shows how you can start a macro with a SCADA BASIC instruction in PcVue. Details: For the example below, Excel must already […]
[KB148] SQL Syntax for SVSQL SCADA Basic Instruction
Applies to: PcVue all versions.While the basic content of this article remains valid, details may have changed since it was written. Summary: This article outlines the SQL syntax to use […]
[KB146] Logging of Alarm Acknowledgements
Applies to: PcVue version 6.04d onwards. Summary: This article describes how to attribute alarm acknowledgement from SCADA Basic to the current user. Details: It is possible to acknowledge alarms from […]
[KB145] Limitations of the ‘IF’ instruction
Applies to: PcVue all versions. Summary: This article describes some limitations of the ‘IF’ instruction Details: In SCADA Basic you cannot combine a test of an register variable and bit […]
[KB144] How to Increase the Number of Symbols in SCADA BASIC Programs and SCADA BASIC limitations
Applies to: PcVue all versions.While the basic content of this article remains valid, details may have changed since it was written. Summary: This article explains how to modify the limit […]
[KB143] How to start a SCADA Basic Program when a mimic opens
Applies to: PcVue all versions. Summary: This article describes how to make a SCADA Basic Program run when a particular mimic opens.From version 11.0 onwards it is not necessary to […]
[KB142] How to Send Messages to the Event Viewer
Applies to: PcVue all versions.While the basic content of this article remains valid, details may have changed since it was written. Summary: This article describes how to run a trace […]
[KB141] How to retrieve mouse coordinates in SCADA BASIC
Applies to: PcVue all versions. Summary: This articles describes how you can retrieve mouse coordinates in a PcVue project. Details: This uses the function GetCursorPos from a Windows DLL, USER32.DLL, […]
[KB140] How to open windows in a particular region using SCADA Basic
Applies to: PcVue version 6.04 onwards. Summary: This article describes how to use SCADA Basic to control the opening of windows in selected regions. Details: There are 2 SCADA Basic […]
[KB139] Date and time formats from SCADA Basic and VBA
Applies to: PcVue all versions. Summary: This article discusses discrepancies in the ways date-time formatting works in PcVue, SCADA Basic, VBA and animations. Details: Calculations of date and time do […]
[KB138] Changing a threshold value by a SCADA BASIC Program
Applies to: PcVue all versions. Summary: This article describes how to modify a threshold value of a register, using SCADA BASIC. Details: When a threshold value of a register variable […]
[KB137] Retrieving memory information with Enable Basic
Applies to: PcVue version 7.00 onwards.While the basic content of this article remains valid, details may have changed since it was written. Summary: This article describes how to retrieve information […]
[KB136] Printing a Window with Enable Basic VBscript
Applies to: PcVue version 7.00c onwards.This article contains obsolete references. Summary: This article outlines methods for printing a Window (or Mimic) with VBscript. Details: There are three ways to print […]
[KB135] Launching an Excel workbook using an Enable Basic script
Applies to: PcVue version 7.00 onwards. This article contains obsolete references. Summary: This article describes how to launch a Microsoft Excel workbook using an Enable Basic script. Details: The sample […]